- load type: resistive or long-, medium- and short wave infrared (IR) lamps
- maximum load current: depending on the connected REVO Sx (3.5-90A) or REVO S (30-800A)
- maximum load voltage: depending on the connected REVO Sx (240Vac/480Vac) or REVO S (480Vac, 600Vac or 690Vac)
- power control input:
- logic input on/off SSR signal (4-30Vdc)
- read by REVO PC from temperature controllers or PLC/DCS system over fieldbus communication interface
- power control outputs: 24x logic output on/off SSR signals to control either REVO Sx or REVO S units
- firing modes:
- single cycle at 50% power demand
- half cycle at 50% power demand (not for 4-8 channel RPC 204-208 2 phase control of star/delta)
- control modes:
- open loop
- power (VxI)
- MODBUS RTU RS-485 and MODBUS TCP ethernet interface
- fuses: inside REVO Sx or REVO S units
- heater break alarm
- thyristor short circuit alarm
- Optional
- ProfiNET and MODBUS TCP interface
- ProfiBUS and MODBUS TCP interface
- Ethernet/IP and MODBUS TCP interface
- REVO KPC SCADA/HMI screen. Up to 24 slaves can be connected
– REVO PC series catalog
– REVO PC serial communication manual
Click here to request a quotation for the REVO PC.
12-24 channel 1 phase independent channels shared on the 3 phases, connection phase to phase

12-24 channel 1 phase channel balanced on the 3 phases, connection phase to neutral

8 channel star without neutral or closed delta connection

8 channel star with neutral connection

REVO Sx multichannel 1 phase units