- load type (specify at ordering):
- 1 phase:
- resistive
- short wave infrared (IR) lamps
- transformer primary side coupled with:
- resistive
- MoSi2 heaters
- SiC
- UV lamp
- MoSi2
- SiC
- 2 phase:
- resistive with 3 phase star without neutral connection
- resistive with 3 phase delta connection
- short wave infrared (IR) lamps with 3 phase star connection
- short wave infrared (IR) lamps with 3 phase delta connection
- MoSi2 (extended version only)
- 3 phase:
- resistive with 3 phase star with neutral
- resistive with 3 phase star or delta connection
- short wave infrared (IR) lamps with 3 phase star connection with neutral
- short wave infrared (IR) lamps with 3 phase delta or star connection
- 3 phase transformer coupled with resistive load
- 3 phase transformer coupled with cold resistance (MoSi2)
- 1 phase:
- maximum load current:
- standard: 30-800A
- extended version: 1100-2100A
- maximum load voltage: 480Vac, 600Vac or 690Vac
- many firing modes with/without soft start:
- half and single cycle soft start for infrared lamp (half cycle only). (1 phase only)
- burst firing
- delayed triggering (1 and 3 phase only)
- phase angle (1 and 3 phase only)
- zero crossing on/off
- many control modes:
- open loop
- voltage
- voltage square (V2)
- current
- current square (I2)
- power (VxI)
- Inputs:
- 0/4-20mA
- 0-10Vdc
- SSR logic signal
- 10k potentiometer
- Very easy configuration with the free APP and USB interface with free configuration software
- fuses included:
- 30-40A: fuse and fuseholder included
- 60-2100A: fixed fuses included
- optional
- current limit
- heater break alarm + SCR short circuit
- analog output for 0/10VDC or 4-20mA retransmission
- fieldbus module for
- MODBUS RTU
- 2x ProfiNET and 1x MODBUS RTU
- ProfiBUS and MODBUS RTU
- 2x MODBUS TCP and 1x MODBUS RTU.
- SCADA/HMI touchpanel that can communicate with up to 6 REVO C units
- PowerManager touchpanel for easy configuration, status indication and remote service of the thyristorunit (with MODBUS RTU RS-485 interface)
– REVO C series catalogue
– REVO C 1 phase 30-40A
– REVO C 1 phase 60-210A
– REVO C 1 phase 300-800A
– REVO C 1 phase 60-800A 690Vac version
– REVO C 1 phase 1100-2100A
– REVO C 2 phase 30-40A
– REVO C 2 phase 60-210A
– REVO C 2 phase 300-800A
– REVO C 2 phase 60-800A 690Vac version
– REVO C 2 phase 1100-2100A
– REVO C 3 phase 30-40A
– REVO C 3 phase 60-210A
– REVO C 3 phase 300-800A
– REVO C 3 phase 60-800A 690Vac version
– REVO C 3 phase 1100-2100A
– PowerManager User Manual
– PowerManager Engineering Manual
Click here to request a quotation for the REVO C.
Test unit: easy online configuration

The free configuration software enables you to easily test and commission the unit in a test-mode. This makes configuration easy and quick.
Process variable logging

The configuration software has a datalogging mode to view the actual status of the control. This helps in finetuning the unit to its load.
REVO C 1 phase features

REVO C 2 phase features

REVO C 3 phase features

PowerManager touchpanel remote status indication of the thyristor unit

With the optional PowerManager touchpanel, that can be connected with the MODBUS RTU RS-485 interface, the status of the thryistorunit can be easily monitored remotely. This can be used for remote-service.
PowerManager for an easy overview of actual power, voltage and current

Easy actual status of actual power, voltage and current to the load.